Mylex PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170 Przewodnik Instalacji

Przeglądaj online lub pobierz Przewodnik Instalacji dla Networking Mylex PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170. Mylex PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170 Installation guide [en] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 82
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
AcceleRAID 170
Installation Guide
DB11-000022-00 First Edition
08P5511
Przeglądanie stron 0
1 2 3 4 5 6 ... 81 82

Podsumowanie treści

Strona 1 - AcceleRAID 170

AcceleRAID 170Installation GuideDB11-000022-00 First Edition08P5511

Strona 3 - 408.433.8000

About This ManualThis installation guide covers hardware set-up and configuration procedures necessary for the installation of a Mylex AcceleRAID 170

Strona 4 - Declaration of Conformity

ConventionsThroughout the manual, the following conventions are used to describe user interaction with the product:prompt This style of type indicates

Strona 5

Manual No. DB11-000022-00 iiiContentsChapter 1IntroductionProduct Description ...

Strona 6 - Community of Europe

iv AcceleRAID 170 Installation GuideOperating System ...3-5Operating System

Strona 7

Manual No. DB11-000022-00 1-1Chapter 1IntroductionThis chapter describes:• The AcceleRAID™ 170 controller• Standard package contents• User supplied

Strona 8 - Copyright Notice

Product Description1-2 AcceleRAID 170 Installation GuideController FeaturesFeatures of the AcceleRAID 170 controller include:• One QLogic ISP 10160A c

Strona 9 - Trademark Acknowledgments

IntroductionManual No. DB11-000022-00 1-3Operating System SupportMS-DOS 5.x, 6.x, and above are supported using drivers that reside in the AcceleRAID

Strona 10

Standard Package Contents1-4 AcceleRAID 170 Installation GuideStandard Package ContentsThe following items are supplied with the standard shipping pac

Strona 11 - About This Manual

IntroductionManual No. DB11-000022-00 1-5User-supplied Items The following user-supplied items are required to perform this installation:• IBM-PC™ com

Strona 12 -  WARNING

Electromagnetic Compatibility NoticesThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This

Strona 13 - Contents

User-supplied Items1-6 AcceleRAID 170 Installation Guide

Strona 14

Manual No. DB11-000022-00 2-1Chapter 2InstallationThis chapter describes:• Before You Begin• Safety Considerations• Installation Checklist• Connectors

Strona 15 - Introduction

Before You Begin2-2 AcceleRAID 170 Installation GuideBefore You BeginInstalling the AcceleRAID 170 single channel RAID controller is no more difficult

Strona 16

InstallationManual No. DB11-000022-00 2-3Safety ConsiderationsBe sure to observe the following precautions before beginning the controller installatio

Strona 17 - Operating System Support

Installation Checklist2-4 AcceleRAID 170 Installation GuideInstallation ChecklistGET READY☛ NoteIt is recommended that you wear a grounded wrist strap

Strona 18 - Standard Package Contents

InstallationManual No. DB11-000022-00 2-5Connectors, LEDs, and JumpersThere is one external and one internal Ultra 160 SCSI connector supported on the

Strona 19 - User-supplied Items

Connectors, LEDs, and Jumpers2-6 AcceleRAID 170 Installation Guide Figure 2-1. AcceleRAID 170 Controller Channel ConnectorsFigure 2-2. AcceleRAID 17

Strona 20

InstallationManual No. DB11-000022-00 2-7Figure 2-3. AcceleRAID 170 Jumper LocationsTable 2-2. AcceleRAID 170 Jumper DescriptionsJ1 Manufacturing test

Strona 21 - Installation

Installation Process2-8 AcceleRAID 170 Installation GuideInstallation ProcessInstalling the ControllerFollow these installation steps:1. Choose any av

Strona 22

InstallationManual No. DB11-000022-00 2-9 CautionBe sure to wear a ground wrist strap at all times.3. Handling the AcceleRAID 170 controller by the e

Strona 23

Interference-Causing Equipment Regulations.Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur

Strona 24 - Installation Checklist

Installation Process2-10 AcceleRAID 170 Installation GuidePreparing the SCSI DrivesTo prepare the drives for installation, follow these steps:1. Remov

Strona 25 - Connectors, LEDs, and Jumpers

InstallationManual No. DB11-000022-00 2-11☛ NoteIn order to ensure an error free environment, the proper cable type designed for a certain SCSI speed

Strona 26 - D1 D2 D4

Installation Process2-12 AcceleRAID 170 Installation Guide1. Termination - Only Internal or Only External Devices Check that the drive channel is prop

Strona 27

InstallationManual No. DB11-000022-00 2-132. Termination - Both Internal and External Devices Check that the drive channel is properly terminated acco

Strona 28 - Installation Process

Installation Process2-14 AcceleRAID 170 Installation GuideSetting SCSI Device IDs4. Set the SCSI ID on the disk drives; ID 7 is reserved for the contr

Strona 29

InstallationManual No. DB11-000022-00 2-15SCSI CablingThe controller supports one Ultra 160 SCSI channel which can support up to 15 SCSI devices (plus

Strona 30 - Preparing the SCSI Drives

Limitations on Mixing SCSI Drives2-16 AcceleRAID 170 Installation GuideLimitations on Mixing SCSI DrivesNarrow with Wide SCSI DrivesIf you mix narrow

Strona 31 - SCSI Termination

Manual No. DB11-000022-00 3-1Chapter 3Controller Start-upThis chapter describes:•BIOS Options • BIOS Configuration Utility (RAID EzAssist)• Operating

Strona 32

BIOS Options3-2 AcceleRAID 170 Installation Guideoption.

Strona 33

Controller Start-upManual No. DB11-000022-00 3-3Setting BIOS OptionsThe available BIOS options are:• BIOS disabled / enabled• CD-ROM boot disabled / e

Strona 34 - SCSI ID Numbers

Declaration of ConformityPer FCC Part 2, Section 2.1077(a)Manufacturer’s Name: LSI Logic Corporation Manufacturer’s Address:North American Headquarter

Strona 35 - SCSI Cabling

BIOS Options3-4 AcceleRAID 170 Installation GuideEnable 8 GByte or 2 GByte Drives This setting affects how the BIOS reads the disk drives for the boot

Strona 36 - LVD with Single-ended Drives

Controller Start-upManual No. DB11-000022-00 3-5☛ NoteIn the event that the RAID controller needs to be replaced, the current drive geometry will be r

Strona 37 - Controller Start-up

Global Array Manager (GAM) Client3-6 AcceleRAID 170 Installation GuideGlobal Array Manager (GAM) ClientThe controller can be configured using GAM. GAM

Strona 38 - BIOS Options

Manual No. DB11-000022-00 A-1Appendix AAcceleRAID 170SpecificationsGeneral Hardware SpecificationsAcceleRAID 170Controller AcceleRAID 170CPU i960RM mi

Strona 39 - Setting BIOS Options

General Hardware SpecificationsA-2 AcceleRAID 170 Installation GuideEnvironmental Specifications Controller AcceleRAID 170Temperature Operating 0°C

Strona 40

Manual No. DB11-000022-00 B-1Appendix BAcceleRAID 170Error Messages☛ NoteThe firmware you are using may have these messages turned off. However, they

Strona 41 - Operating System

Installation AbortB-2 AcceleRAID 170 Installation GuideDuring the initialization, if the firmware fails to respond to the BIOS inquiry within two minu

Strona 42 - In Case of Problems

AcceleRAID 170 Error MessagesManual No. DB11-000022-00 B-3to the RAID EzAssist Configuration Utility User Reference Guide or RAID EzAssist Configurati

Strona 43 - Specifications

System Reboot or Power DownB-4 AcceleRAID 170 Installation Guide

Strona 44

Manual No. DB11-000022-00 C-1Appendix CPCI Hot PlugIntroductionPCI Hot Plug is a feature that allows a PCI card to be replaced while the host system i

Strona 45 - Error Messages

Declaration of ConformityPer 89\336\EECResponsible PartyName:LSI Logic Corporation Address:North American HeadquartersMilpitas, CAU.S.A.hereby declare

Strona 46 - Installation Abort

ImplementationC-2 AcceleRAID 170 Installation Guide• odineb.nlm - This is a module combining the Open Data-link interface and the Novell Event Bus (NE

Strona 47

PCI Hot PlugManual No. DB11-000022-00 C-3Windows NTWindows NT requires additional software from the vendor who makes the system. Since this software i

Strona 48 - System Reboot or Power Down

ImplementationC-4 AcceleRAID 170 Installation Guidethe PCI Hot Plug capability. No additional software is required.Please refer to the Windows XP or .

Strona 49 - PCI Hot Plug

Manual No. DB11-000022-00 D-1Appendix DEnclosure ManagementIntroductionMylex’s AcceleRAID controllers support the industry standard enclosure manageme

Strona 50 - Implementation

SESD-2 AcceleRAID 170 Installation GuideSESThe AcceleRAID 170 supports SES (SCSI Enclosure System) cabinets. Please refer to the documentation supplie

Strona 51

Manual No. DB11-000022-00 G-1GlossaryAcceleRAID™The AcceleRAID family features high performance, cost effective Ultra SCSI/Ultra2 SCSI LVD and Ultra 1

Strona 52

G-2 AcceleRAID 170 Installation GuideAutomatic RebuildMylex controllers provide automatic rebuild capabilities in the event of a physical disk drive f

Strona 53 - Enclosure Management

GlossaryManual No. DB11-000022-00 G-3BusA set of conductors that connect the functional units in a computer and are the channels through which data is

Strona 54

G-4 AcceleRAID 170 Installation GuideChannelAny path used for the transfer of data and control of information between storage devices and a storage co

Strona 55 - Glossary

GlossaryManual No. DB11-000022-00 G-5DiskA non-volatile, randomly addressable, re-writable data storage device, including rotating magnetic and optica

Strona 56

Community of EuropeCE mark is rated for the AceleRAID 170 as follows: CISPR 22 Radiated EmissionEN55022, Generic immunity standard for the following:I

Strona 57 - Manual No. DB11-000022-00 G-3

G-6 AcceleRAID 170 Installation Guideactive controllers (also called Active/Active controllers) are connected to the same set of devices and provide a

Strona 58

GlossaryManual No. DB11-000022-00 G-7eXtremeRAID 1100, 2000, and 3000 provide the highest performance and most flexible RAID solution available today.

Strona 59 - Manual No. DB11-000022-00 G-5

G-8 AcceleRAID 170 Installation GuideGigabyte230 (1,073,741,824) bytes. Abbreviated as G or GB.Global Array Manager (GAM)A Mylex RAID management utili

Strona 60

GlossaryManual No. DB11-000022-00 G-9controller to “rebuild” the data on the new drive, all without interrupting system operations. Once the rebuild i

Strona 61 - Manual No. DB11-000022-00 G-7

G-10 AcceleRAID 170 Installation GuideI/OInput/Output, the transmission of information between an external source and the computer.I/O BusAny path use

Strona 62

GlossaryManual No. DB11-000022-00 G-11Logical Drive StatesA logical (system) drive can be Online, Critical, or Offline. Notice that the term “online”

Strona 63 - Manual No. DB11-000022-00 G-9

G-12 AcceleRAID 170 Installation GuideMirroringRefers to the complete duplication of data on one disk drive to another disk drive, this duplication oc

Strona 64

GlossaryManual No. DB11-000022-00 G-13OfflineA Logical Drive is in an “offline” state if no data can be read from it or written to it. Offline does no

Strona 65

G-14 AcceleRAID 170 Installation GuidePhysical DeviceAny device connected to some kind of hardware. For example, SCSI disk, fibre disk, network disk,

Strona 66 - Narrow SCSI

GlossaryManual No. DB11-000022-00 G-15RAID LevelsMylex disk array controllers support four RAID Advisory Board approved (RAID 0, RAID 1, RAID 3, and R

Strona 67

Underwriters Laboratories Statement and Warning

Strona 68

G-16 AcceleRAID 170 Installation GuideRAID MigrationA feature in RAID subsystems that allows for changing a RAID level to another level without poweri

Strona 69 - RAID Levels

GlossaryManual No. DB11-000022-00 G-17enclosure itself is treated as simply another device on the SCSI bus. Many other leading server, storage, and RA

Strona 70

G-18 AcceleRAID 170 Installation GuideOffline: A SCSI disk drive is in a “offline” state if it is not present, if it is present but not powered on, or

Strona 71 - SCSI Drive States

GlossaryManual No. DB11-000022-00 G-19reported, conservative cache is enabled and all system drives are switched to write-through cache. Primarily use

Strona 72

G-20 AcceleRAID 170 Installation GuideTo use the standby rebuild feature, you should always maintain a standby SCSI disk in your system. When a disk f

Strona 73 - SAME DAC960 controller

GlossaryManual No. DB11-000022-00 G-21drive 1, block 2 on SCSI drive 2, block 3 on SCSI drive 3, block 4 on SCSI drive 1, block 5 on SCSI drive 2, and

Strona 74 - Striping

G-22 AcceleRAID 170 Installation GuideUltra SCSI (Fast 20 SCSI)A high performance SCSI protocol that has a bus speed of 20 Megabytes per second in the

Strona 75

Manual No. DB11-000022-00 Index-1IndexAAborted Installation B-2AcceleRAID 170 1-1capabilities 1-2channels 1-2features 1-2operating system support 1-4s

Strona 76

Index-2 AcceleRAID 170 Installation Guideoperating system support 1-3PPCI Hot Plug C-1Implementation C-1Introduction C-1NetWare C-1Windows 2000 C-3Win

Strona 77

LSI LOGIC CORPORATIONSOFTWARE LICENSE AND WARRANTY POLICYLimited WarrantyLSI warrants to the original purchaser of the product enclosed herein(“Custom

Strona 78

Proprietary Rights NoticeThis document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used b

Strona 79 - LSI LOGIC CORPORATION

with LSI’s instructions and the terms of this Agreement, shippingcosts to be borne by LSI, and (c) Customer has provided proof ofpurchase price and da

Strona 80

is a part of the Product (“LSI Software”) solely as part of the Productincorporated into the OEM Products that and not on a standalonebasis. Customer

Strona 81

Manual No. DB11-000022-0008P5511LSI Logic CorporationNorth American HeadquartersMilpitas, CA408.433.8000

Strona 82

Trademark AcknowledgmentsLSI Logic, the LSI Logic logo, MORE, Mylex, and SANmapping are trademarks or registered trademarks of LSI Logic Corporation.

Komentarze do niniejszej Instrukcji

Brak uwag